Title: Mutual Solubility Curve For Phenol and Water
Date of Practical
10 November 2016
Objective
To measure the miscibility temperatures of several phenol-water mixtures of known composition and to determine the critical solution temperature for phenol-water system.
Introduction
There are certain liquids miscible with each other in all proportions
which when it is mix together to mixture appear as only one phase, for example
is the ethanol and water. While some have limited proportions miscibility in
other liquids, which it may appear as two phases at first but with the changes
of temperature it will become in one phase, for example: ether-water and
phenol-water.
At low and high percentage of phenol, water and phenol form a single
liquid phase indicate that it mix completely. As for phenol and water, both
liquids become more soluble when the temperature is increased until a certain
temperature or also called as its critical solution temperature. However, above
this critical point the liquid will then become completely miscible. The water
and phenol phase diagram near or above room temperature contains a solid phase.
Any pair of liquids may form a closed system which both upper and lower
critical solution temperatures exist but both temperatures are not easy to be
determined before the substance freezes or evaporates. At any temperature below
the critical solution temperature, the composition for two layers of liquids in
equilibrium state is constant and does not depend on the relative amount of
these two phases. The mutual solubility for a pair of partially miscible
liquids in general is extremely influenced by the presence of a third
component.
Material
Phenol, water.
Apparatus
Test tube, parafilm, aluminium foil, thermometer, water bath, test tube holder, measuring cylinder.
Procedures
1. A 15 mL mixture of phenol and water is prepared in test tubes containing 8%, 30%, 50%, 65% and 80% of phenol in the mixture.
2. A thermometer is
placed inside each test tube and the test tubes are sealed with parafilm.
4. The temperature at
which the turbid liquid becomes clear is observed and recorded.
5. The test tubes are
removed from the water bath and allowed for temperature to reduce gradually, until the liquid becomes turbid and two layers are separated. The temperature
at which the liquid becomes turbid is recorded.
6. The average
temperature at which two phases are no longer seen or at which two phases exist
is determined.
7. A graph of phenol
composition in the different mixtures against temperature at complete
miscibility is plotted. The critical solution temperature is determined.
Discussion
In this experiment, a total of 30 mL mixture of phenol and water with different percentage of phenol composition is prepared in test tubes. The sealed test tube is then heated in water bath and removed from the water bath when the two layers were disappeared and the turbid liquid became clear. Then, it is allowed for the temperature to reduce gradually and the temperature when the liquid became turbid and two layers formed is recorded. The average temperature when two phases were no longer seen is determined and the graph of the percentage of phenol composition in water against temperature at complete miscibility is plotted. The experiment was repeated twice in order to get precise results.
In this experiment, a total of 30 mL mixture of phenol and water with different percentage of phenol composition is prepared in test tubes. The sealed test tube is then heated in water bath and removed from the water bath when the two layers were disappeared and the turbid liquid became clear. Then, it is allowed for the temperature to reduce gradually and the temperature when the liquid became turbid and two layers formed is recorded. The average temperature when two phases were no longer seen is determined and the graph of the percentage of phenol composition in water against temperature at complete miscibility is plotted. The experiment was repeated twice in order to get precise results.
The average temperature for 8%, 30%, 50%,
65% and 80% of phenol composition in water are 47.48, 65.38, 64.50, 54.00 and
34.00˚C respectively. The graph plotted is a diagram phase with two components
containing liquid phase condensed system which is used in practice to achieve a
single liquid phase product, which are phenol and water. The bell-shaped curve
shows the limits of temperature and concentration within which two liquid
phases exist in equilibrium. The region outside the curve is a single liquid phase
while the region inside the curve is a two liquid phase.
The maximum temperature at which the two-phase
region exists is called the critical solution temperature. The critical
solution temperature in this experiment is 67˚C. At intermediate compositions
and below the critical temperature, mixtures of phenol and water separates into
two distinct layers.
A line drawn across the region is termed a
“tie line” where all systems prepared on a tie line, at equilibrium, will
separate into two distinct layers or phases of constant composition. These
phases are termed conjugate phases. This tie line is always parallel to the
base line in two-component systems. However, when a system is prepared out of
the tie line, for example, when phenol is added to 100% water gradually at a
fixed temperature, which is 50˚C, a homogenous phase will be seen, but only
until a certain level. The same goes when after another certain point, the
addition of phenol to water becomes homogenous again. In this experiment, at
temperature 50˚C, the composition of phenol in water where the mixture starts
to become heterogeneous is 11% and the composition of phenol in water where the
mixture becomes a homogenous solution is 68%.
The upper consolute temperature obtained
from this experiment which is 67˚C is slightly deviated from the theoretical
value which is 66.8˚C. This is due to the evaporation of some phenol to the
surrounding.
There are a few precautions that should be
taken to avoid occurrence of error. First, the eye must be perpendicular with the
meniscus level of phenol and water so that the parallax error could be reduces.
The boiling tube must be sealed tightly together with the thermometer to avoid
evaporation of phenol when it is added with water. Next, place the thermometer
inside the tube and seal it tightly to avoid any heat escapes during the
heating process. Phenol must be transferred inside the fume hood to avoid it
from evaporates as it is a highly volatile substance. While handling the
experiments, we should wear glove, mask and goggle to avoid any injury during
experiments. Then, the boiling tube must be handle with care as it may fall and
break. Rinse and clean every apparatus before using it to avoid from
contaminating the solutions. While heating, the temperature cannot be too hot
as it will cause the phenol to evaporate easily. Lastly, swirl the solutions
slowly and do not use the thermometer to stir the solutions during heating
process, as the thermometer may break.
There are some errors that occur in this
experiment. First, the amount of phenol and water are not accurately measured due to parallax error. Besides, the temperature recorded are not accurately
taken when the liquid became homogeneous. The parafilm may not be wrapped tightly to cover the top
of the boiling tubes that may have cause a faster loss of heat to the surrounding which alters the temperature.
Question
1.
Discuss the
diagrams with reference to the phase rule.
A useful device for relating the effect of the least
number of independent variables upon various phases that can exist in an
equilibrium system containing a given number of components is known as the
phase rule. It is expressed as F = C ‒ P + 2 in which F is the number of
degrees of freedom in the system, while C is the number of components and P is
the number of phases present in the system. The number of degrees of freedom is
the least number of intensive variables (temperature, pressure, concentration, refractive
index, density, viscosity, etc) that must be fixed to describe the system
completely. The degree of freedom depends on the number of components and the
phases that coexist.
In this experiment, the pressure of the system is
maintained. Therefore, the degree of freedom is the temperature and the
chemical composition. Applying the phase rule, at condition when phenol and
water are miscible, this two-component system is in one liquid phase and the
degree of freedom is F = 2 ‒ 1 + 2 = 3. Because the pressure of the system is
fixed, F is reduced to 2. Both temperature and concentration need to be fixed
to define this system.
When phenol and water are immiscible with each other,
where two distinct layers can be seen, the degree of freedom is F = 2 – 2 + 2 =
2. The two degrees of freedom are temperature and percentage of phenol
composition in water. In this system, the pressure is fixed. Hence, only
temperature is needed to completely define the system as F is reduced to 1.
2.
Explain the effect
of adding foreign substances and show the importance of this effect in
pharmacy.
The effect of adding foreign substances to
binary system results in ternary system. If the substance added only soluble in
one of the component, or if the solubilities in both liquids are very
different, the mutual solubility will decreased. This will then causes the
upper consolute temperature to increase and the lower consolute temperature to
decrease. On the other hand, if the substance soluble in both liquids, the
mutual solubility will increase and cause the upper consolute temperature to
decrease and lower consolute temperature to increase. This effect of adding
foreign substances in pharmaceutical preparations may cause an insoluble
complexes and leads to inefficiency of biological availability of drug.
Conclusion
The phenol-water exists as two-phase system in range
of 8% to 80% at constant temperature. The critical solution temperature is 67˚C.
Above this temperature at any composition of phenol, the system will be
completely miscible. Below this temperature, the mixture separates into two
distinct layers. To define this system of two-phase system, two variables,
which are temperature and pressure must be fixed. When temperature is known, it
is possible to completely duplicate this system as the concentration of phenol
can be determined.
Reference
Campbell,
F. C. (2012) Phase Diagrams:
Understanding the Basics. USA: ASM International
Phase diagrams of pure substances Retrieved from www.chemguide.co.uk/physical/phaseeqia/phasediags.html
[10 Dicember 2016]
Zhao,
J. C. (2007) Methods for phase diagram
determination. Elsevier Publications